STEELmobile type Z
Choose type
 |
Technical specifications :
|
|
Z800C |
Z1300C |
Z1600C |
Z2200C |
| Power |
kW |
81,7 |
134,2 |
174,8 |
220,9 |
| Air flow |
m³/h |
6500 |
8000 |
12000 |
17000 |
| Light oil consumption |
kg/h |
6,89 |
11,30 |
14,74 |
18,60 |
| Natural gas consumption |
m³/h |
8,27 |
13,60 |
17,70 |
22,35 |
| LPG consumption |
kg/h |
6,25 |
10,25 |
13,86 |
16,90 |
| Fuel |
|
light oil / ON / LPG / GZ |
light oil / ON / LPG / GZ |
light oil / ON / LPG / GZ |
light oil / ON / LPG / GZ |
| Capacity |
% |
91 |
90 |
91 |
90 |
| Air exit temperature* |
oC |
thermostatic reg. |
thermostatic reg. |
thermostatic reg. |
thermostatic reg. |
| Power consumption |
kW |
0,75 |
1,1 |
1,5 |
2,2 |
| Electrical power |
V/Hz |
1-230/50 |
1-230/50 |
3-400/50 |
3-400/50 |
| Chimney diameter |
(fi) |
150 |
200 |
200 |
200 |
| Hot air exit diameter |
(fi) |
500 |
600 |
700 |
700 |
| Fuel container capacity |
L |
external container |
external container |
external container |
external container |
| Fuel pressure |
bar |
depends on burner type |
depends on burner type |
depends on burner type |
depends on burner type |
| Size |
mm |
1970 x 830 x 1275 |
1880 x 1000 x 1460 |
3000 x 1140 x 1755 |
3000 x 1140 x 1755 |
| Packing size |
mm |
2070 x 840 x 1270 |
2400 x 950 x 1500 |
3100 x 1250 x 1800 |
3100 x 1250 x 1800 |
| Netto weight |
kg |
180 |
260 |
305 |
320 |
| Brutto weight |
kg |
220 |
320 |
365 |
385 |
| Quantity of units on one base |
pcs |
1 |
1 |
1 |
1 |
*temperature checked in 1 m from air exit and in +15oC in room
|
|
Z800E |
Z1300E |
Z1600E |
Z2200E |
| Power |
kW |
81,7 |
134,2 |
174,8 |
220,9 |
| Air flow |
m³/h |
6500 |
8000 |
12000 |
17000 |
| Light oil consumption |
kg/h |
6,89 |
11,30 |
14,74 |
18,60 |
| Natural gas consumption |
m³/h |
8,27 |
13,60 |
17,70 |
22,35 |
| LPG consumption |
kg/h |
6,25 |
10,25 |
13,86 |
16,90 |
| Fuel |
|
light oil / ON / LPG / GZ |
light oil / ON / LPG / GZ |
light oil / ON / LPG / GZ |
light oil / ON / LPG / GZ |
| Capacity |
% |
91 |
90 |
91 |
90 |
| Air exit temperature* |
oC |
thermostatic reg. |
thermostatic reg. |
thermostatic reg. |
thermostatic reg. |
| Power consumption |
kW |
0,5 |
1,1 |
1,1 |
1,3 |
| Electrical power |
V/Hz |
1-230/50 |
1-230/50 |
3-400/50 |
3-400/50 |
| Chimney diameter |
(fi) |
150 |
200 |
200 |
200 |
| Hot air exit diameter |
(fi) |
500 |
600 |
700 |
700 |
| Fuel container capacity |
L |
external container |
external container |
external container |
external container |
| Fuel pressure |
bar |
depends on burner type |
depends on burner type |
depends on burner type |
depends on burner type |
| Size |
mm |
1620 x 830 x 1275 |
1840 x 1000 x 1460 |
2400 x 1140 x 1755 |
2400 x 1140 x 1755 |
| Packing size |
mm |
1720 x 840 x 1270 |
1960 x 950 x 1500 |
2500 x 1250 x 1800 |
2500 x 1250 x 1800 |
| Netto weight |
kg |
150 |
220 |
280 |
305 |
| Brutto weight |
kg |
180 |
250 |
310 |
335 |
| Quantity of units on one base |
pcs |
1 |
1 |
1 |
1 |
*temperature checked in 1 m from air exit and in +15oC in room
|
|